PLANT PRO SYSTEM SPECIFICATIONS · Power supply: North American model: 120VAC, 60Hz, 15Amps International model: 230VAC, 50Hz · Internal current consumption: Less than 0.5 Amp · Outlets: Four outlets: Lamp, Pump, Fan, and CO2 12 Amps each outlet, 14.5 Amps total · Outlet relay minimum life: 1,000,000 operations mechanical 100,000 operations electrical at 3324VA switching · Display: LED, four digits, 0.5" height, 7 segment Indicators for colon, AM, PM, °F, rH, PPM, and Photo ·Temperature Sensor: 32-110 °F, usable with reduced accuracy to 5 °F sensor accuracy +/- 1 °F at 77 °F (typical) sensor response time 100% of reading in 4 minutes resolution of 1 °F ·Humidity Sensor: 0-100% rH sensor accuracy +/- 2% 15 second time constant resolution of 1% rH · CO2 Sensor: 0-2000 PPM sensor accuracy +/- 50 PPM typical resolution of 10 PPM · Photocell Sensor: 0-100, arbitrary scale resolution of 1 unit · Flood Sensor: Conductivity type, threshold at approximately 1mSiemens continuous conductivity for 1-2 seconds required for response safe low voltage/low current, maximum of 5 volts DC, .000003 Amps · Analog/digital processing: A/D conversion +/- 1%, +/- 1 digit digital filtering time constant 2.1 seconds response time with 0-100% input change for 0-100% output change 13 seconds · Time keeping: 12 hour with AM/PM mode or 24 hour mode (factory set) accuracy is based on power line frequency stability @ 50 or 60 Hz (factory set) · Remote connector: Reserved for future peripherals including Panic circuit · Case dimensions: 9.875" x 7.875" x 2.5" (not including knobs or power cord)